By Omron Electronics Inc-EMC Div 70
DC power relays capable of DC loading at high voltage and current actualize improvement of inrush-withstand performance and a long-life by adopting Omron’s own contact driving system. The relays actualize a high capacity interruption through the function of extinction of magnetic arc by adopting high-efficiency magnetic circuit.
Coil ratings | ||||||
Rated voltage | Rated current | Coil resistance | Must-operate voltage | Must-release voltage | Maximum voltage | Power consumption |
12 VDC | 100 mA | 120 Ω | 60% max. of rated voltage | 5% min. of rated voltage | 130% of rated voltage (at 23°C within 10 minutes) | Approx. 1.2 W |
24 VDC | 50 mA | 480 Ω |
Contacts rating | |||
Rated load | Rated carry current | Maximum switching voltage |
Maximum switching current |
15 A at 400 VDC | 15 A | 400 V | 15 A |